User manual
  X K 3 1 9 0C 602   
Annex A Error Prompt Message 
Table A-1 Error Prompt Message Explanation 
Error 
Prompt 
Message 
Explanation  Handling method 
[Error ] 
[ 1] 
Tare requirement is not met.  Tare after getting stable. 
[Error ] 
[ 2] 
Requirement of zero-setting is 
not met. 
Set  zero  after  getting 
stable. 
[Error ] 
[ 3] 
Input  parameter  exceeds 
allowed range. 
Input  the  parameter 
correctly. 
[Error ] 
[ 4] 
EEPROM  Hardware  is 
damaged 
Replace U15, U16 on main 
board 
[Error ] 
[ 5] 
Calibration data is wrong, and 
the parameter is initialized. 
Recalibrate  and  reset  all 
parameters. 
[Error ] 
[ 6] 
Printer wire is not connected 
or  printer  is  faulty.  Skip  by 
pressing any key. 
Check  printer  setting  or 
connection condition 
[Error ] 
[ 7] 
Calibration  switch  is  not 
turned  on  during  parameter 
calibration  or  calibration 
parameter modification   
Turn on calibration switch 
before  recalibration  or 
calibration  parameter 
modification 
[Error ] 
[ 8] 
The loaded weight is too small 
or loading weight parameter is 
input wrong during calibration 
Weight  loaded  should  be 
more  than  1/5  of  max. 
weighing limit; the weight 
around  weighing  limit  is 
better. 
[Error ] 
[ 9] 
Batching  value  is  too  small, 
startup fails. 
Set  quantitative  scale 
parameter correctly 
[Error ] 
[ 10] 
Upper  limit  sequence  of 
batching scale is wrong   
Set upper limit sequence of 
batching scale correctly 
[Error ] 
[ 11] 
Zero-setting scope is exceeded, 
zero-setting fails 
Check  conditions  of  load 
carrier  and  transducer,  or 
make recalibration 
[Error ] 
[ 12] 
Zero-setting scope is exceeded, 
zero-setting fails 
Check  conditions  of  load 
carrier  and  transducer,  or 
make recalibration 
[Error ] 
[ 20] 
Real  time  oscillator  stopping 
vibration 
Check, replace crystal Y1, 
capacity  C21,  C22, 
resistance R31 
[Error ] 
X=2~9EEPROM writing is 
Check and replace U15 or 