User manual
  X K 3 1 9 0C 602   
II. 
External Control mode
  Suppose high speed batching scale is provided at site: Industrial control PLC will combine 
with the  instrument  to sort  out the cargos quickly. PLC will control the cargo to the weighing 
platform.  A  signal  will  be triggered  to  the  instrument  after  the  cargo  is  loaded  to  make  the 
weighing platform calculate the weight. The weight scope of the users’ qualified product is 9.90kg 
~ 10.10kg and the channel signal, which can be controlled by PLC to deliver to different channels, 
will be  sent according to the weight scope. The time for  one cycle is  about  3~5 seconds. The 
instrument should be used together with PLC. We can set the parameter in SET 2 according 
to table 8-3 (suppose that there are 2 decimal digits during calibration): 
Table 8-3 Parameter Setting Example of Batching scale in External Control Mode 
  Set parameter 13A inSET 1to 3. Set parameter inSET 2as follows: 
Parameter
Setting  Instruction 
1 
[ 1] 
[CtrL ] 
Choose the peak holding mode. 
2 
[ 02] 
[t0 ] 
The cargo is already on the weighing 
platform  when the triggering signal is 
received.  Long  time  delay  is  not 
required 
3 
[ 10] 
[t1 ] 
It is enough to take 1 second to calculate 
the weight. 
4 
[ 00] 
[t2 ] 
Inform  PLC  to  move  the  cargo 
immediately  after  calculation  is 
finished.  Long  time  delay  is  not 
required. 
5 
[ 10] 
[t3 ] 
Send the channel signal with interval of 
1 second  and ensure  it is  received by 
PLC. 
6 
[000400] 
[L ] 
Set  zero  zone,  which  should  be  totally 
different form the qualified lower limit. 
7 
[000990] 
[A ] 
Qualified lower limit 
8 
[001010] 
[b ] 
Qualified upper limit 
9 
[999999] 
[C ] 
It is suggested to set the unused channel 
to the max. value. 
10  [999999]  It is suggested to set the unused channel 