User manual
  X K 3 1 9 0C 602   
Fig 8-1 Time Sequence of Catchweigher in Self-control Mode 
Brief introduction of control procedure of batching scale in self-control mode (Please refer to 
the sequence order figure): 
(1) The instrument starts to run and it will judge whether the weight is higher than zero zone. If it 
is  higher, then  enter  t0  delay  to  wait  for  the  cargo  to  be  completely  loaded  to the  weighing 
platform; 
(2) Time t0 is over and the instrument will start to calculate the average weight of cargo with time 
interval of t1. The value calculated will be the reference for batching scale signal; 
(3) Time t1 is over and the instrument will enter the t2 delay to wait for the cargo to leave the 
weighing platform; 
(4) Time t2 is over and the instrument will send the sorted channel signal to make the cargo enter 
the corresponding channel; 
(5) Sending signal is finished and the instrument will judge whether the weight is back to the zero 
zone again. Only when the zero zone is entered, would the next cycle be started. 
  Table 6-2 describes the working process of batching scale in self-control mode in forms of 
the program step. 
Display method
of program step
 Set parameter 17B ofSET  0to 4. Under running status, 










