User manual
  X K 3 1 9 0C 602   
Chapter 8 Application Examples of Batching scale 
I. Self Control Mode 
  If belt weighing scale is provided at the control site, the user has to choose three different 
cargoes of different weights through the belt. The weights of these three cargos are respectively 
5kg, 10kg and 15kg and it will be delivered through the belt every 10 seconds. The interval for the 
cargo to be on and off the weighing platform is about 2 seconds and cargo will be remained at the 
weighing platform for about 4 seconds. We can set the parameter inSET 2as follows (suppose 
that it is 2 decimal digits during calibration) 
Table 8-1 Parameter Setting Example of batching scale in Self Control Mode 
  Set the parameter 13A ofSET 1to 3. The parameter setting ofSET 2is as follows: 
Parameter
Setting  Instruction 
1 
[ 0] 
[CtrL ] 
Choose the non-peak holding mode. 
2 
[ 20] 
[t0 ] 
The  time  to load the  weighing  platform  is  about  2 
seconds. 
3 
[ 40] 
[t1 ] 
The time for remaining on weighing platform is about 
4 seconds. 
4 
[ 20] 
[t2 ] 
The time for cargo to be unloaded from weighing 
platform is about 2 seconds. 
5 
[ 20] 
[t3 ] 
Send the channel signal with interval of 2 seconds 
6 
[000400] 
[L ] 
Other interference can be removed if the zero zone is 
big 
7 
[000750] 
[A ] 
It is easier to choose if the intermediate value of the 
two cargos is set. 
8 
[001250] 
[b ] 
It is easier to choose if the intermediate value of the 
two cargos is set. 
9 
[001750] 
[C ] 
Ensure the third cargo loads on this scope. 
10 
[999999] 
[d ] 
It is  suggested to  set  the unused  channel  to  max. 
value. 
Please refer to Fig 8-1 for the control sequence order: 