User manual
  X K 3 1 9 0C 602   
execute the procedure repeatedly. 
  4.  If  the  remaining  material  weight  is  less  than  the  min.  weight  (i.e.d1+d2)  of  one  time 
material  feeding  weight  plus  material  in  the  hopper,  the  instrument  will  be  stopped  to  do  the 
material feeding and wait for the Add Signal (it means material charging is allowed, that is, feed 
material to the hopper); The output control signal of material discharging of the instrument will be 
valid after there is an Add Signal and it will start to judge the weight. If the material weight in the 
hopper is added to the weight confirmed by the parameter A2, the material discharging will be 
stopped and the material feeding cycle which is just stopped will continue. 
  For example: the batching value of material 1 is 50 kg, the batching value of material 2 is 
150kg and the min. remaining weight b2 is 20kg. If the remaining weight in the hopper is less than 
70 kg when the cycle is started, the material should be added to the hopper up to over150kg to 
start the material feeding. 
  Table 6-2 describes the working process of the quantitative scale subtraction by program step. 
Display method of program step
 Set Parameter 7BSET  0to 4; under the running status, 
the auxiliary display of  the instrument  will show current program  step number in the forms of 
‘Step**’. 
Table 6-2 Description of Program Step of Subtracting Quantitative Scale 
Program 
step 
Description 
1  If  the  hopper  weight  is  less  than  the  min.  material  weight  plus 
batching value, go to program step 13. 
Wait for the stable display light to be ON and the Add Signal to be 
valid, it will enter the status of negative scale, the timer will be T0 
and go to program step 2. 
2  Start the quick feed. If T1 is 0, start the slow feed at same time. 
The timing  T0 is over and weight inspection is started.  If the 
loaded value reaches to batching value minus quick feed lead, turn 










