User manual
  X K 3 1 9 0C 602   
  Subtracting scale is to control the material (i.e. the material feed) weight discharged by the 
control  hopper.  Please  refer  to  Fig  6-2 for  the function  and the  meaning of  setting parameters 
during the process and the sequence order for controlling the input and output: 
Figure 6-2 Working Sequence Drawing of Subtracting Quantitative Scale 
The parameter instruction in the Figuret0Measurement delay of material feedt1Quick feed over delay
t2 Slow feed over delayThe instrument during the three periods will not judge the weightd1Quantitative 
value of feedq1Quick feed lead of material 1; a1Slow feed lead of materialo1 Allowance of material 
b2:Min. remaining weight of material; A2:Charging weight of material 
Note to working process of subtracting quantitative scale: 
1. The Add Signal is needed before material feeding; 
2. The Discharge Signal is needed during material discharging; 
3. If the Add Signal and Discharge Signal are always valid, the indicator will automatically 