User manual

X K 3 1 9 0C 602
Subtracting scale is to control the material (i.e. the material feed) weight discharged by the
control hopper. Please refer to Fig 6-2 for the function and the meaning of setting parameters
during the process and the sequence order for controlling the input and output:
Figure 6-2 Working Sequence Drawing of Subtracting Quantitative Scale
The parameter instruction in the Figuret0Measurement delay of material feedt1Quick feed over delay
t2 Slow feed over delayThe instrument during the three periods will not judge the weightd1Quantitative
value of feedq1Quick feed lead of material 1; a1Slow feed lead of materialo1 Allowance of material
b2:Min. remaining weight of material; A2:Charging weight of material
Note to working process of subtracting quantitative scale:
1. The Add Signal is needed before material feeding;
2. The Discharge Signal is needed during material discharging;
3. If the Add Signal and Discharge Signal are always valid, the indicator will automatically