User manual

X K 3 1 9 0C 602
V. Print
Print Print the current weightunder non operating, non setting status.
Remark: Please confirm the parameter setting of the printer type before printing to avoid
printing mistake.
VI.
Data Query and Removal
Method to Save Weighing Data
Set Parameter B in Parameter 9 of SET 1as 1, the quantitative scale will
automatically save the actual weight of each quantitative cycle. If it is set to 2, then the
quantitative scale will automatically save the finishing time and actual weight of each quantitative
cycle. The accumulation cant be performed manually.
Inquiry Method
PressSetting8Input8Input8Inputinquire the total accumulated times
8Inputinquiry the total accumulated weight. Press button6or5 during the query.
If the option at right side of lower line shows ’1’, press buttonInputto print the accumulated
times and accumulated weight. If the option shows ‘2’, press buttonInputto print all weighing
records. Press buttonExitto end printing weighing record halfway.
The communication port2of PC can also be used to read the weighing record.
Accumulated Value Removal
Press button Input after the accumulated value is displayed and the indicator will
indicate , which means whether to remove the accumulated data. Press button 5
8Inputto clearand pressInputdirectly not to clear.
The communication port2of PC can also be used to clear the weighing record.
VII. Operation /Stop
Press the buttonOperationon the indicator panel to start the cycle.
If the buttonStop is pressed, the indicator will enter the status of ‘pre-stop’ and the light of
‘stop’ and ‘operation’ will be ON at same time. It will be stopped after the cycle is completed. If
the buttonStopis pressed once again under the status of ‘pre-stop’, it will enter the ‘pause status.
Then the indicator will stop action, all outputs will be shut down and the signal lamp ‘function’
and ‘stop will all be OFF. If the button Operationis pressed again, the indicator will be restored
[ AB]
[
Auto P
]
[
0]
[
dEL
]