User manual
  X K 3 1 9 0C 602   
air  and  has  not  reached  to  the  load  carrier.  To  obtain  the  predetermined material  weight, it  is 
necessary to turn off the feeder in advance. The weight involved in the leading is called a lead. For 
C602, “self-correction of lead” function can be activated to ensure the accuracy of final weight.   
Gradual feed When the feeding to quantitative scale is finished, the material weight is less than 
the predetermined weight and the difference is beyond the tolerance, the indicator can start slow 
feeding repeatedly and shortly to make the loaded weight approach to the predetermined value. 
Add signal is short for “adding input signal is allowed”. Only when the add signal is valid can the 
C602 output feeding control signal. 
Discharge signal is short for “discharge input signal is allowed”. Only when discharge signal is 
valid can C602 output discharge control signal. 
Zero zone is the  weight limit in additive scale  which is  used to  judge  whether the  material in 
hopper is completely discharged. 
 1.  During  discharging,  it  is  deemed  completed  when  the  indicator  shows  the  gross weight  is 
below zero zone. 
 2. The indicator can print and totalize only when the material weight is above zero zone.   
  For  catchweigher,  the  self-control catchweigher can start weighing process only when  the 
weight signal is above zero zone and can print and sum when the calculation result of material 
weight is above zero zone. 
Additive scale is the quantitative scale used for batching control of added material weight in load 
carrier (like hopper etc), for example, the hopper-type quantitative packing scale. 
Subtracting scale is the quantitative scale used for batching control of subtracted material in the 
load carrier (like hopper). It is also called weight loss scale. 
Negative scale is the indicator to measure the weight removed from the load carrier. Subtracting 
scale works as negative scale during feeding. 
Channel is the range of object weight. C602 indicator can be divided into 5 weight ranges, also 
called 5 channels. Each channel has 1 corresponding switch output signal. 
Out-of-tolerance treatment When it is valid and the materials fed by quantitative scale is less 
than the lower limit of batching value (subtracting tolerance of batching value), while there is no 
gradual feed function, or when the fed material is more than the upper limit of set value (additive 
tolerance of batching value), the quantitative scale will stop running, waiting for manual treatment. 
When  the  weight  meets  the  tolerance  requirement,  the  quantitative  scale  will  resume  the 
interrupted work. 
Peak holding When the catchweigher captures an object weight, it  will be displayed  until the 
weight of next object is captured. The main display or auxiliary display can be selected to show 