User manual
  X K 3 1 9 0C 602   
11 
[******] 
[0_Zone] 
Zero zone 
1. T
he discharge is deemed over 
when the indicator 
shows the gross 
weight is below zero zone. 
2. The indicator
 can print and sum 
only  when  the  gross 
weight  is 
above zero zone. 
12 
[ ***] 
[t0 ] 
Feed  measuring  delay  (0.0  ~  25.5
seconds)
A
void  misjudgment  of  weight 
c
aused  by  the  weight  impact  at 
startup
13 
[ ***] 
[t1 ] 
Measurement  delay  of  quick  feed 
over (0.0 ~ 25.5 seconds) 
When t1 = 0
, quick feed and slow 
quick are activated at same time. 
14 
[ ***] 
[t2 ] 
Measurement delay of slow feed over
(0.0 ~ 25.5 seconds) 
15 
[ ***] 
[t3 ] 
Gradual feed output time (0.0 ~ 25.5
seconds) 
16 
[ ***] 
[t4 ] 
Interval  time  of  gradual  feed  (0.0
  ~ 
25.5 seconds) 
17 
[ ***] 
[t5 ] 
Qualified  output  time  (0.0  ~  25.5
seconds) 
18 
[ ***] 
[t6 ] 
Discharge  over  delay  (0.0  ~  25.5
seconds) 
19 
[ ***] 
[t7 ] 
Re-feed delay (0.0 ~ 25.5 seconds)   
20 
[  A] 
[Print?] 
A—
whether  to  print  parameter 
setting 
(0: no printing: 1: printing) 