User manual
  X K 3 1 9 0C 602   
SET 2control parameters
  Refer to table 4-4 and 4-5 according to different value of SET 1 parameter 13A. 
Table 4-4 Parameter 2 of Quantitative Scale 
(when 0 or 1 is selected for parameter 13A inSET 1in table 4-3) 
Param
eter 
Indicator 
display 
Parameter explanation  Remarks 
1 
[ ABC] 
[CtrL ] 
Batching control parameters 
Aselection of self-correction of lead 
(0: no correction, 1: correction) 
B  selection  of  out-of-
tolerance 
treatment 
(0:  no  treatment,  continue  operation;
1: wait for treatment until it is qualified)
Cgradual feed for material shortage 
(0: no gradual feed, 1
: gradual feed for 
material shortage) 
2 
[ *****] 
[Pt ] 
Cycle index
Set the cycle index (0 ~ 65535, 0
means  indefinite)  in  the 
full 
process from feed to discharge
3 
[******] 
[A1 ] 
Batching of material 1 
4 
[******] 
[b1 ] 
Quick feed lead of material 1 
5 
[******] 
[C1 ] 
Slow feed lead of material 1 
6 
[******] 
[d1 ] 
Material 1 allowance. 
7 
[******] 
[A2 ] 
Additive scale: batching of material 2
Subtracting scale: weight of feed 
I
f material 2 is not needed, please 
set this batching value as zero. 
8 
[******] 
[b2 ] 
A
dditive  scale:  quick  feed    lead  of 
material 2 
S
ubtracting  scale:  minimum  weight 
of material in hopper 
9 
[******] 
[C2 ] 
Slow feed lead of material 2 
T
his  parameter  is  useless  for 
subtracting scale 
10 
[******] 
[d2 ] 
Material 2 allowance 
This  parameter
  is  useless  for 
subtracting scale 