User manual
  X K 3 1 9 0C 602   
8 
[ AB] 
[PL ] 
A—selection of printing language  
(0: English; 1: Chinese) 
B—printing direction 
(0: no reverse printing, 1: reverse printing)
Parameter B
 is only effective 
for  micro  printer.  A
s  for 
panel-instal
led  micro  printer, 
selecting  reverse  printing  is 
easy  for  checking  printing 
result. 
9 
[ AB] 
[Auto P] 
A—automatic printing 
(0: no print, 1: automatic print) 
B—automatic data saving 
(0: no saving, 1: saving weight, 2
: saving 
time and weight) see note 1 
If parameter A is set as 1
, the 
quantitative  scale
  will 
automatically print the actual 
discharge  quantity  each  time 
and  the  catchweigher  will 
print the weight of material
measured each time. 
10 
[******] 
[Aout_W] 
T
he  corresponding  weight  at    full 
range of analog output 
When this weight is reached, the indicator
will output analog value at full range. 
T
his value can be larger than 
the max. weighing value
, but 
the  max.
  output  value  is  the 
corresponding  value  at  max.
weighing. W
hen this value is 
smaller  than  the  max.
weighing value
, the full range 
of analog output
 will remain 
unchanged. 
11 
[******] 
[Aout_0] 
DA internal code (0-20000
) at zero point 
of analog output 
(output 4-20mA signal about 12520; 
 Output 0-5V/0-10V is 0) 
T
he zero point of calibration 
analog  output
  of  this 
parameter can be modified. 
12 
[******] 
[Aout_F] 
DA  internal  code  (10000-65535)
  at full 
range of analog output 
(4-20mA output about 62590; 
 0-5V/0-10V output about 65200) 
T
he  full  range  value  of 
calibration  analog  output
of  this  parame
ter  can  be 
modified. 
13 
[ ABC] 
[type ] 
Aworking mode of the indicator  
(0: additive scale, 1: subtracting scale, 2
: 
self-control  catchweigher,  3
:  external 
control catchweigher) 
Bparameters number (0-4) 
Cweight unit 
(0: mg, 1: g, 2: kg, 3: t) 
E
xternal  control 
catchweigher  mode:  the 
indicator  w
ill  only  measure 
weight upon being activated 
by external control signal; 
Self-
control  catchweigher: 
the  indicator
  automatically 
starts  weighing  when  the 
weight  is  larger  than  zero 
zone value. 
14 
[  A] 
[Print?] 
A-whether to print parameter setting 
(0: No: 1: Yes) 










