User manual
  X K 3 1 9 0C 602   
C  Filter 
Weak 
A
  little 
weak 
Mediu
m 
A
  little 
strong 
S
trong 
difficult  for  the  stability
indicating  lamp
  to  light  on 
when  the  weight  is  less 
stable.  When  the  stability
indicating  lamp
  is  not  on, 
zero-setting, tare
 and printing 
operation  cannot  be  carried 
out. U
ser can adjust relevant 
parameter according to actual 
need. 
4 
[ **] 
[Addr  ] 
Indicator communication address (01
 ~ 
26) 
When  several  indicator
s  communicate 
with  PC  through  the  RS422/485
  bus, 
communication  address
es  can  be  used  to 
distinguish them. 
Communication baud rate (0 ~7) 
A-communication  interface  (1)
, 
B-communication interface (2) 
A,B  0  1  2  3 
BPS 
600  1200  2400  4800 
A,B  4  5  6  — 
5 
[ AB] 
[bAud ] 
BPS 
9600  19.2k  57.6k 
— 
Communication mode 
A-communication  interface  (1)
, 
B-communication interface (2) 
A  0  1  2 
Communicati
on mode 
Continuously 
send 
AD code 
Continuously 
send weight 
Used as 
printing 
interface 
B  0  1  2 
6 
[  AB] 
[t Mode ] 
Communicati
on mode 
Command 
response 
mode  
Continuous 
send mode 
RS485mode 
T
he times of sending data per 
second  by  communication 
interface (1) equal to the AD
conversion rate. 
T
he  sending  rate  of 
communication  interface  (2
) 
in continuous send mo
de is 
about  10
  times  per  second. 
RS485
  mode  can  only  be 
used  in  command  response 
mode. 
Printer model  (0 ~ 4) 
A  0  1  2  3  4 
7 
[  A] 
[Prn ] 
Printer 
model 
No 
printer 
Micro 
printer 
LT800 
(9 
needle) 
Panasoni
c 
KX-P 
1121 
EPSON 
1600K 
T
he  listed  printer  model  is 
the  typical  one.  P
rinter  with 
compatible  communication 