Specifications

6–56 EPSON Rev. 2.1
S1D12400 Series
t
AH8
t
CC
t
CYC8
t
DS8
t
DH8
A0, CS
WR
D0 to D7
t
AH8
11. AC CHARACTERISTICS
System Bus Write Characteristics I (80 series MPU)
Item Signal Symbol
Measuring
Min. Max. Unit
condition
Address hold time A0, CS t
AH8 –30ns
Address setup time t
AW8 –60ns
System cycle time WR t
CYC8 300 ns
Control pulse width (Write) t
CC –60ns
Data setup time D0 to D7 t
DS8 –60ns
Data hold time t
DH8 –50ns
[VSS = –5.5 V to –4.5 V, Ta = –30 to 85°C unless otherwise specified]
*1: At the fall and rise time of input signals, set 15 ns or less.
*2: Every timing is specified on 20% and 80% of V
SS.
*3: The same timing is not required for A0 and CS. Input signals so that A0 and CS may satisfy
tAW8 and tAH8
respectively.
Item Signal Symbol
Measuring
Min. Max. Unit
condition
Address hold time A0, CS t
AH8 –30ns
Address setup time t
AW8 –60ns
System cycle time WR t
CYC8 500 ns
Control pulse width (Write) t
CC 100 ns
Data setup time D0 to D7 t
DS8 100 ns
Data hold time t
DH8 –50ns
[VSS = –4.5 V to –2.4 V, Ta = –30 to 85°C unless otherwise specified]
[VSS = –2.4 V to –1.8 V, Ta = –30 to 85°C unless otherwise specified]
Item Signal Symbol
Measuring
Min. Max. Unit
condition
Address hold time A0, CS t
AH8 –30ns
Address setup time t
AW8 –60ns
System cycle time WR t
CYC8 1000 ns
Control pulse width (Write) t
CC 200 ns
Data setup time D0 to D7 t
DS8 200 ns
Data hold time t
DH8 –50ns