(3-1) Selecting the Standby mode
End of initialization
Normal operation
(Power Save is released and
oscillator circuit is turned ON.)
Command input:
(1) Display on/off control command
• D: Off (Display)
(2) Power save command
• PS: On (Power save)
• O: On (Oscillation)
(3) Power control commands
• P, VF, VC: Off
Standby status
Static display control
commands can be used.
(Note 2)
(Note 2)
(3-2) Releasing the Standby mode
Standby mode
Command input:
(1) Display on/off control command
• D: On (Display)
(2) Power save command
• PS: Off (Power save)
• O: On (Oscillation)
Input of electronic volume register
command
• Data: (0, 0, 0, 0)
Input of power control commands
• P, VF, VC: Off
Input of electronic volume register
command
• Data: Appropriate value
Return to normal operation (initial status).
(Note 2)
(Note 2)
Note 2: Commands (1) and (2) can be entered in any order. Also, command (1) is optional.
Note 3: Commands (1) and (2) can be entered in any order. Also, command (1) is optional.
(Note 3)
(Note 3)
(Note 3)
(Note 3)
(4-1) Selecting the Sleep mode
End of initialization
Normal operation
(Power Save is released and
oscillator circuit is turned ON.)
Command input:
(1) Display on/off control command
• D: Off (Display)
(2) Power save command
• PS: On (Power save)
• O: Off (Oscillation)
(3) Power control commands
• P, VF, VC: Off
Enter the Sleep mode.
(4-2) Releasing the Sleep mode
Sleep mode
Command input:
(1) Display on/off control command
• D: On (Display)
(2) Power save command
• PS: Off (Power save)
• O: On (Oscillation)
Wait for 20 msec or more.
Input of electronic volume register
command
• Data: (0, 0, 0, 0)
Input of power control commands
• P, VF, VC: On
Input of electronic volume register
command
• Data: Appropriate value
Return to normal operation