Specifications
1-42 Command Descriptions Rev. A
Reading status:
Readable fonts:
FS b
[Name] Request retransmission of check paper reading result
[Format] ASCII FS b
Hex 1C 62
Decimal 28 98
FS b retransmits the previous check paper (MICR character) reading results. The transmitted
information is the same as that previously sent by FS a 0. If FS a 0 is not executed before FS b, the
printer transmits the reading status as "not normal."
Bit Off/On Hex Decimal Function
0
Off 00 0
Readable fonts. See the table below.
On 01 1
1
Off 00 0
On 02 2
2, 3 — — — Undefined.
4
Off 00 0 Rereading possible.
On 10 16 Rereading not possible.
5
Off 00 0 Reading normal.
On 20 32 Reading not normal.
6 On 40 64 Not used. Fixed to On.
7 Off 00 0 Not used. Fixed to Off.
Bit 1Bit 0Font
Off Off E13B
Off On CMC7
On Off Undefined
On On Undefined
Program Example
PRINT #1, CHR$(&H1C);"b";