Specifications

Confidential
SHEET
96
NO.
SHEET
REVISION
H
TITLE
NEXT
97
TM-U590 series
Specification
(STANDARD)
ESC D n1 ... nk NUL
[Name] Set horizontal tab positions
[Format] ASCII ESC D n1 ... nk NUL
Hex 1B 44 n1 ... nk 00
Decimal 27 68 n1 ... nk 0
[Range] 1 n 255
0 k 32
[Description] Sets horizontal tab positions.
n specifies the column number for setting a horizontal tab position from the
beginning of the line.
k indicates the total number of horizontal tab positions to be set.
[Notes] The horizontal tab position is stored as a value of [n × character width] measured
from the beginning of the line. The character width includes the right-side
character spacing, and double-width characters are set with twice the width of
normal characters.
This command cancels the previous horizontal tab settings.
When setting n = 8, the print position is moved to column 9 by sending HT.
Up to 32 tab positions (k = 32) can be set. Data exceeding 32 tab positions is
processed as normal data.
Transmit [n]k in ascending order and place a NUL code 0 at the end.
When [n]k is less than or equal to the preceding value [n]k-1, tab setting is
finished and the following data is processed as normal data.
ESC D NUL cancels all horizontal tab positions.
The previously specified horizontal tab positions do not change, even if the
character width changes.
The character width is used with the one in the mode when this command is
executed.
[Default] n = 8, 16, 24, 32... (intervals of 8 characters (columns 9, 17, 25,...) for the font A
(9 × 9).)
[Reference] HT