Operator`s manual
5-30 Commands
First byte (printer information)
Second byte (error information)
Bit Off/On Hex Decimal Status for ASB
0 Off 00 0 Not used. Fixed to Off.
1 Off 00 0 Not used. Fixed to Off.
2
Off 00 0 Drawer kick-out connector pin 3 is LOW
On 04 4 Drawer kick-out connector pin 3 is HIGH.
3
Off 00 0 On-line.
On 08 8 Off-line.
4 On 10 16 Not used. Fixed to On.
5 Off 00 0 Not used. Fixed to Off.
6
Off 00 0 Paper feed button is not used.
On 40 64 Paper feed button is used.
7 Off 00 0 Not used. Fixed to Off.
Bit Off/On Hex Decimal Status for ASB
0
Off 00 0 Undefined.
On 01 1 Undefined.
1
Off 00 0 Undefined.
On 02 2 Undefined.
2
Off 00 0 Undefined.
On 04 4 Undefined.
3
Off 00 0 Undefined.
On 08 8 Undefined.
4 Off 00 0 Not used. Fixed to Off.
5
Off 00 0 No unrecoverable error.
On 20 32 Unrecoverable error.
6
Off 00 0 Undefined.
On 40 64 Undefined.
7 Off 00 0 Not used. Fixed to Off.