Specifications

CONFIDENTIAL
Paper roll Counter printing commands GS C 1
Ver. 10.05 p. 708
The value of the counter is updated when executing GS c by following the counter mode set by this
command.
In a count-up setting, when the GS c is executed and the counter value exceeds the maximum value
(bL + bH × 256), counting is restarted from the minimum value (aL + aH × 256).
In a count-down setting, when GS c is executed, the counter value is below minimum value
(bL + bH × 256), restart counting from the maximum value (aL + aH × 256).
In a count-stop setting, when executing GS c, the counter value is not changed.
The settings for a range of a counter set by GS C ;, stepping amount of incrementing or decrementing of
a counter value, the repetition number of printing is disabled by processing this command.
Settings of this command are effective until GS C ; is executed, ESC @ is executed, the printer is reset, or
the power is turned off.