Specifications
No
EPSON
TITLE
EPSON Advanced Printer Driver for TM series
StatusAPI
Reference Manual
Revision
L
NEXT
106
SHEET
105
<4> If the type is “WDO”
“Return size”
Format output when returned from the port monitor.
Return Size: The size of the data returned from the port monitor is output in hexadecimal character string
format.
Output if 0x00000010 or 0x00000100 is specified in LogLevel.
<5> If the type is “WPI”
”Write request size
Format that is output when sending print data from the printer driver.
Write request size: The write request size to the port monitor is output in hexadecimal character string
format.
Output if 0x00000010 or 0x00000100 is specified in LogLevel.
<6> If the type is “WPO”
“Return Size”
Format that is output when returning from the port monitor
Return Size: The written size of data returned from the port monitor is output in hexadecimal character
string format.
Output if 0x00000010 or 0x00000100 is specified in LogLevel.
<7> If the type is “RDI”
“Read Request Size”
Format that is output when receiving data from the API.
Read Request Size: The read request size to the port monitor is output in hexadecimal character string
format.
Output if 0x00000010 or 0x00000100 is specified in LogLevel.
<8> If the type is “RDO”
“Return size, read data”
Format that is output when data are returned from the port monitor.
Return Size: The read size of data returned from port monitor is output in hexadecimal character string
format.
Read Data: Read data from the port monitor are output in hexadecimal character string format.
Output if 0x00000010 or 0x00000100 is specified in LogLevel.
<5> If the type is “STD” ,“EDD” or “RPN”
None.
Output if 0x00000010 or 0x00000100 is specified in LogLevel.
•
Variable length binary log (EpsStmMon.bin) format
The latest print data are treated as 1 job of binary data.
Output if 0x00000100 is specified in the LogLevel.
• Variable length binary log (
EpsScnImg.bin/EpsScnImgR.bin
) format
Converts the latest image reading data and retransmission image data to binary data.
Image data change to the format specified by the BiSCNSetImageFormat function.
Output if 0x00001000 is specified in the LogLevel
<1> Shows the log output results in the case that the maintenance counter (number of paper feed lines) is
acquired.
Reference: int BiGetCounter(int nHandle, WORD readno, LPDWORD eradcounter)
[EpsStmApi.log]
“20010409130000.000,FUI,000000FF,BiGetCounter,00000001,0014,00000000CRLF”
“20010409130001.000,FUO,000000FF,BiGetCounter,00000001,0014,000007D0,<00000000>CRLF”