3.71. BiSetMonEtherInterval
[Function]
A status API that specifies the interval of the status information from the Ethernet connection printer which is expressed in
seconds.
[Format]
int BiSetMonEtherInterval (int nHandle, WORD wEtherInterval);
[Argument]
int nHandle
Specifies the handle value of the printer to change the interval. The BiOpenMonPrinter() return value is used in the handle
value.
WORD wEtherInterval
Specifies the interval to get information from the Ethernet connection printer expressed in seconds.
[Return value]
0 is returned when changing the interval to get information from the printer is successful.
The following error codes (less than
zero) are returned when an error is triggered.
ERR_HANDLE The handle value specified for the printer is incorrect.
ERR_PARAM Specified interval in milliseconds is less than or equal to zero.
ERR_NOT_SUPPORT Not supported by this printer.
[Explanation]
If this function is not called, a default value exists. It is 2 seconds.
[Caution]
When using this function and the interval mode is very long, the serial reception buffer overflows and the right status notice
become unreliable.
[Supported printer]
TM-T88II, TM-T88III, TM-T90, TM-L90, TM-H5000II, TM-U590, TM-U675, TM-H6000, TM-H6000II, TM-J8000,
TM-J2000/2100, TM-J7000/7100, TM-U230, TM-U210A, TM-U325, TM-U950, TM-U295, TM-L60II