Specifications

Hardware 2-17
TM-H6000/H6000P Developer’s Guide
Confidential
Operating temperature and humidity range
Vibration resistance: When packed:
Frequency: 5 to 55 Hz
Acceleration: 2 G
Sweep: 10 minutes (half cycle)
Duration: 1 hour
Directions: x, y, and z
No external or internal damage should be found after the
vibration test, and the unit should operate normally.
Impact resistance: When packed:
Package: EPSON standard package
Height: 50 cm (19.69")
Directions: 1 corner, 3 edges, and 6 surfaces
No external or internal damage should be found after the
drop test, and the unit should operate normally.
When unpacked:
Height: 5 cm (1.97")
Directions: Lift one edge and release it (for all 4 edges).
When the printer is not printing, no external or internal
damage should be found after the drop test.
Ambient
temperature
[˚C]
[% RH]
Relative humidity
Operating environment
range
34 ˚C, 90 %
40 ˚C, 65 %
45 ˚C, 50 %
90
80
60
20
40
10
0
0 10 20 30 40 50
34
°
C(93
°
F), 90%
40
°
C(104
°
F), 65%
45
°
C(113
°
F), 50%