Specifications
110
Receive Buffer
You can set the receive buffer of the TM-H6000IV to 4 KB or 45 bytes with DIP switch 1-2 as with
the TM-H6000III. The buffer full condition of the TM-H6000IV is the same as that of the
TM-H6000III.
Memory Capacity
The sizes of the download buffer and NV graphics data of the TM-H6000IV are the same as those
of the TM-H6000III.
Electrical Characteristics
The operating voltage of the TM-H6000IV is DC 24V ± 7%. The current consumption differs,
depending on the print duty.
DIP Switches
The functional assignments of DIP switches are the same as those of the TM-H6000III except for
DIP switches 2-3 and 2-4, and DIP switches 1-7 and 1-8 for the serial interface model.
Printer Status
The TM-H6000IV goes to the same status under the same conditions as the TM-H6000III. You can
replace the TM-H6000IV with the TM-H6000III without modifying applications.
Logo Registration
The TM-H6000IV can register logos in the NV memory (NVRAM) with the TM-H6000IV Utility,
while the TM-H6000III can register logos with the TM Flash LOGO Setup Utility for NVRAM
(TM-Flogo).
TM-H6000IV TM-H6000III
Operating voltage
DC 24V ± 7% DC 24V ± 10%