APPENDIX E: TRANSMISSION STATUS IDENTIFICATION
Because the specified status bits transmitted from the TM-H5000II are fixed, the user can
confirm the command to which the status belongs, as shown in the following table.
Command & Function Status Reply
GS I
I I
I (Printer ID)
<0∗∗0∗∗∗∗>B
GS I
I I
I (Header of printer information)
<01011111>B
GS r
<0∗∗0∗∗∗∗>B
XON <00010001>B
XOFF
<0∗∗1∗∗11>B
DLE EOT 1~5
<0∗∗1∗∗10>B
ASB (1st byte)
<0∗∗1∗∗00>B
ASB (2nd to 4th bytes)
<0∗∗0∗∗∗∗>B
(When the printer is used with the MICR reader.)
Command & Function Status Reply
FS a 0, FS b (header)
<01011111>B or <00110111>B
DLE EOT BS 1
<0∗∗1∗∗10>B
When the printer receives header (<5F>H) transmitted when FS a 0, FS b, FS g 2, or GS g 2 is