Specifications
Confidential
SHEET
201
NO.
SHEET
REVISION
I
TITLE
TM-H5000II
IIII
II series
Specification
(STANDARD)
NEXT
202
• When n = 1 or 49 and m = 1 or 49 (to add detailed information), the transmitted
data block of the reading result with the FS a 0 consists of [Header + Reading
status + Detailed information + Separation flag + Reading data + NUL].
• The header consists of one or two bytes, specified with n = 3 or 51.
<Detailed information when an error occurs>
Information Hex
Decima
l
No error has occurred. (Normal end) 40 64
FS a 0 command is not executed yet.
41 65
The check insertion waiting state has been cancelled with the
command.
42 66
The check insertion waiting state has been cancelled because
the time which is set with ESC f command has passed.
43 67
A check whose size is out of the specified range is inserted. 44 68
A magnetic waveform cannot be detected. 45 69
The character which cannot be recognized is detected. 46 70
An error has occurred during the processing of FS a 0
command.
47 71
An error has detected when the noise is observed. 48 72
The process of FS a 0 command is aborted due to the cover
open.
49 73
• The separation flag consists of one byte (Hex = 1FH / Decimal = 31)
• The reading data is added when the reading result with the FS a 0 is ‘normal
end’, or when an error ending occurs in the condition that the number of ‘?’is less
than m in n = 0 or 48 and m ≠ 0.
• NUL consists of one byte (Hex = 00H / Decimal = 0).
• When n = 2 or 50 and m = 0 or 48 (to end the MICR function if an error occured
without the reading data, if an error which does not add the data has occured,
after the printer transmits the reading status, the printer selects the paper roll as
a paper source, and disables the MICR function.
• In either one of the following cases, the printer remains enabling the MICR
function even after reading result is transmitted. In this case, the printer does not
eject the check paper and does not change the MICR status.
➀ When the reading result is normal end.
➁ Even if the Error Ending is occured when n = 0 or 48 and m ≠ 0 (to replace the
unrecognized character with ‘?’) and when the reading data is added to the
reading result.
➂ Even if the errir Ending is occured, when n = 2 or 50 and m = 1 or 49 (to
continue the MICR function) and when the cause of the error ending is
recognized by the printer.
[Reference] FS a 0