Specifications

Confidential
SHEET
199
NO.
SHEET
REVISION
I
TITLE
TM-H5000II
IIII
II series
Specification
(STANDARD)
NEXT
200
FS ( f p
L
p
H
[n m]1...[n m]k
[Name] Select MICR data handling
[Format] ASCII FS ( f p
L
p
H
[n m]1...[n m]k
Hex 1C 28 66 p
L
p
H
[n m]1...[n m]k
Decimal 28 40 102 p
L
p
H
[n m]1...[n m]k
[Range] 2 (p
L
+ p
H
× 256) 65535 (0
pL
255, 0
pH
255)
0 n 3, 48 n < 51
0 m 255
[Default] Always m = 0 for each n
[Description] Selects the MICR reading operations as follows:
p
L
, p
H
specifies (pL + pH × 256) for the number of bytes after
p
H
([n m]1...[n m]k).
n specifies the MICR reading operations as follows:
n Function
0, 48 Specifies to process for character which cannot be recognized.
1, 49 Specifies to add detailed information for the reading result
2, 50 Specifies the condition to disable/enable the MICR function when
reading error has occurred
3, 51 Specifies the header of the transmitted data
m specifies the operations in each process.
When n = 0 or 48, m specifies to process for the character which cannot be
recognized.
m Function
0 The recognition process is aborted when the character which
cannot be recognized is aborted when the character which
cannot be recognized is detected.
1 – 255 The recognition process is continued and the character which
cannot be recognized is replaced with the character ‘?’. If the
number of the characters which are replaced with ‘?’ is less than
m, the data is added to the reading result.