Specifications

Confidential
SHEET
181
NO.
SHEET
REVISION
I
TITLE
TM-H5000II
IIII
II series
Specification
(STANDARD)
NEXT
182
Special characters are defined by combining two characters "{" and one
character. The ASCII character "{" is defined by transmitting "{" twice
consecutively.
Transmit data
Specific character ASCII Hex Decimal
SHIFT {S 7B, 53 123,83
CODE A {A 7B, 41 123, 65
CODE B {B 7B, 42 123, 66
CODE C {C 7B, 43 123, 67
FNC1 {1 7B, 31 123, 49
FNC2 {2 7B, 32 123, 50
FNC3 {3 7B, 33 123, 51
FNC4 {4 7B, 34 123, 52
“{“ {{ 7B, 7B 123, 123
[Example] Example data for printing "No. 123456"
In this example, the printer first prints "No." using CODE B, then prints the following
numbers using CODE C.
GS k 73 10 123 66 78 111 46 123 67 12 34 56
If the top of the bar code data is not the code set selection character, the printer
stops command processing and processes the following data as normal data.
If the combination of "{" and the following character does not apply to any special
character, the printer stops command processing and processes the following
data as normal data.
If the printer receives characters that cannot be used in the special code set, the
printer stops command processing and processes the following data as normal
data.
The printer does not print HRI characters that correspond to the shift characters
or code set selection characters.
The HRI character for the function character is space.
HRI characters for the control characters (<00>H to <1F>H and <7F>H) are
space.
<Others> Be sure to keep spaces on both right and left sides of a bar code. (Spaces are
different depending on the types of bar code.)
[Reference] GS H, GS f, GS h, GS w, Appendix H