GS ^ r t m
[Name] Execute macro
[Format] ASCII GS ^ r t m
Hex 1D 5E r t m
Decimal 29 94 r t m
[Range] 0 ≤ r ≤ 255
0 ≤ t ≤ 255
m = 0, 1
[Description] Executes a macro.
• r specifies the number of times to execute the macro.
• t specifies the waiting time for executing the macro.
• m specifies macro executing mode.
When m = 0:
The macro executes r times continuously at the interval specified by t.
When m = 1:
After waiting for the period specified by t, the PAPER OUT LED indicator
blinks and the printer waits for the FEED button to be pressed. After the
button is pressed, the printer executes the macro once. The printer
repeats the operation r times.
[Details] • The waiting time is t × 100 ms for every macro execution.
• If this command is received while a macro is being defined, the macro definition
is aborted and the definition is cleared.
• If the macro is not defined or if r is 0, nothing is executed.
• When the macro is executed (m = 1), paper cannot be fed by using the FEED,
FORWARD, or REVERSE buttons.
[Reference] GS :