Specifications
Confidential
SHEET
164
NO.
SHEET
REVISION
I
TITLE
TM-H5000II
IIII
II series
Specification
(STANDARD)
NEXT
165
GS W n
L
n
H
[Name] Set printing area width
[Format] ASCII GS W n
L
n
H
Hex 1D 57 n
L
n
H
Decimal 29 87 n
L
n
H
[Range] 0 ≤ n
L
≤ 255
0 ≤ n
H
≤ 255
[Description] Sets the printing area width to the area specified by n
L
and n
H
.
• The printing area width is set to [(n
L
+ n
H
× 256) × horizontal motion unit)] inches.
Printable area
Left margin Printing area width
[Details] • This command is effective only when processed at the beginning of the line.
• In page mode, the printer executes only internal flag operations.
• This command does not affect printing in page mode.
• If the [left margin + printing area width] exceeds the printable area, [printable
area width - left margin) is used.
• The horizontal and vertical motion units are specified by GS P. Changing the
horizontal and vertical motion units does not affect the current left margin.
• The horizontal motion unit (x) is used for calculating the printing area width. The
calculated result is truncated to the minimum value of the mechanical pitch.