Specifications

Confidential
SHEET
164
NO.
SHEET
REVISION
I
TITLE
TM-H5000II
IIII
II series
Specification
(STANDARD)
NEXT
165
GS W n
L
n
H
[Name] Set printing area width
[Format] ASCII GS W n
L
n
H
Hex 1D 57 n
L
n
H
Decimal 29 87 n
L
n
H
[Range] 0 n
L
255
0 n
H
255
[Description] Sets the printing area width to the area specified by n
L
and n
H
.
The printing area width is set to [(n
L
+ n
H
× 256) × horizontal motion unit)] inches.
Printable area
Left margin Printing area width
[Details] This command is effective only when processed at the beginning of the line.
In page mode, the printer executes only internal flag operations.
This command does not affect printing in page mode.
If the [left margin + printing area width] exceeds the printable area, [printable
area width - left margin) is used.
The horizontal and vertical motion units are specified by GS P. Changing the
horizontal and vertical motion units does not affect the current left margin.
The horizontal motion unit (x) is used for calculating the printing area width. The
calculated result is truncated to the minimum value of the mechanical pitch.