Specifications
Confidential
SHEET
95
NO.
SHEET
REVISION
I
TITLE
NEXT
96
TM-H5000II
IIII
II series
Specification
(STANDARD)
n = 1: Printer status
Bit Off/On Hex Decimal Function
0 Off 00 0 Not used. Fixed to Off.
1 On 02 2 Not used. Fixed to On.
2 Off 00 0 Drawer open/close signal is LOW (connector pin 3).
On 04 4 Drawer open/close signal is HIGH (connector pin 3).
3 Off 00 0 Online.
On 08 8 Offline.
4 On 10 16 Not used. Fixed to On.
5,6 - - - Undefined.
7 Off 00 0 Not used. Fixed to Off.
• The printer enters offline when the printer cover is open while printing is stopped.
• The printer enters recoverable error status when the slip paper mode is selected
and enters automatic recoverable error status when paper roll mode is selected,
when cover is open during printing.
n = 2: Offline status
Bit Off/On Hex Decimal Function
0 Off 00 0 Not used. Fixed to Off.
1 On 02 2 Not used. Fixed to On.
2 Off 00 0 Cover is closed.
On 04 4 Cover is open.
3 Off 00 0 Paper is not being fed by using the PAPER FEED button.
On 08 8 Paper is being fed by the PAPER FEED button.
4 On 10 16 Not used. Fixed to On.
5 Off 00 0 No paper-end stop.
On 20 32 Printing is being stopped.
6 Off 00 0 No error.
On 40 64 Error occurs.
7 Off 00 0 Not used. Fixed to Off.
Bit 5: Becomes on when the paper roll end sensor detects paper end and printing stops.