Image Quality Diagnosis and Repair
Horizontal Banding:
1. Perform a Nozzle Check from the Adjustment menu within Self-Diagnostic Mode.
1.1 Inspect printed pattern for missing, deflected or sympathetic nozzle(s).
1.1.1 Perform 2 Cleaning Cycles then reprint Nozzle Check.
1.1.1.1 Missing or deflected nozzle(s)
1.1.1.1.1 Clean the three Caps, Wipers, and Wiper Cleaners and repeat cleaning
cycles.
1.1.1.1.2 Inspect the Cap Assemblys and replace if it is damaged.
1.1.1.1.3 Replace the Print Head.
1.1.1.2 Sympathetic nozzle(s)
1.1.1.2.1 Replace the Print Head.
2. Verify that the paper is not binding:
2.1 While loading.
2.2 While ejecting.
2.3 On the spindle.
3. Verify the Head Slant alignment is correct (A13 Slant)
3.1 Print and inspect the pattern.
3.2 Perform adjustment if required.
4. Verify Platen Gap, with the Printer Settings section, of the SelecType Menu.
4.1 Two settings are available: Standard and Wide.