Service manual
Stylus Pro 10600 Field Repair Guide 7/29/04
Firmware History Printer Component, Software Item, LCD Display, Printer Button Page 57.
Firmware History
Stylus Pro 10600 Current Firmware Ver. TP01627.2527.1726
Release date :February 12th, 2002
1. A 90 second wait time was added between cuts to allow the Cutter Solenoid to cool.
2. The installation information for the Photo Accelerator Module and Type-B interface Card was
added to the Adjustment Variable Print sheet, in Self-diagnostics mode.
3. The Print Head is now capped if AC power is removed when in the Self-diagnostics mode,
preventing damage to the Print Head and the Cleaning/Capping Station .
4. Horizontal banding was resolved by modifying the paper feed value for the following media.
4.1 Enhanced Matte
4.2 Poster Board
4.3 Smooth Fine Art Paper (Sheet)
4.4 Textured Fine Art Paper (Sheet)
5. Service request 00010006 is resolved when executing the Test -> Sensor in the Self-diagnostics
mode. During initializing of the Printer, the Carriage no longer hits against the Right Side Frame.
6. The default value for the Bi-d adjustment is changed to the center value used in the production
line.