Service manual

Epson Stylus Photo PX650/TX650/TX659/PX660/PX660 Premium/Artisan 635 Revision C
DISASSEMBLY AND ASSEMBLY Removal of Exterior Parts 66
Confidential
4.2.4 Upper Housing/Scanner Cable Cover
Parts/Components need to be removed in advance: None
Removal procedure
1. Open the Scanner Unit.
2. Release the hook of the Scanner Cable Cover and remove it in the direction of the
arrow.
Figure 4-10. Removing the Scanner Cable Cover
3. Close the Scanner Unit and remove the screws (x2) of the hinge part.
Figure 4-11. Removing the Upper Housing (1)
C H E C K
P O I N T
The Scanner Unit cannot be opened enough to use a general
screwdriver for removing the screws that secure the Upper
Housing; therefore, this section describes removing the Scanner
Unit before removing the Upper Housing.
The screws that secure the Upper Housing can be removed with a
L-shaped screwdriver, a stubby driver or a similar tool without
removing the Scanner Unit, in that case, you can skip the step 3 to
5 (p.67).
Figure 4-9. L-shaped Screwdriver and Stubby Driver
L-shaped screwdriver
Stubby driver
Scanner Cable Cover
Scanner Unit
Left inside
Rib
Hook
Middle Housing
C.B.P. 3x10 (6±1 Kgfcm)
1
2
Rear upper