Service manual

Epson Stylus Photo PX650/TX650/TX659/PX660/PX660 Premium/Artisan 635 Revision C
TROUBLESHOOTING Troubleshooting When There is Error Display 48
Confidential
DC error
(PF motor)
FBH PF acceleration lock error
An error occurred in the PF
motor operating sequence
Checking the PF mechanism by visual inspection:
Check the PF mechanism for paper jam or adhesion of foreign matters by visual
inspection.
Checking the operation of the PF mechanism:
Operate the PF mechanism by hand, and check to see if it operates smoothly.
Making the following adjustments:
Bi-D Adjustment
PF Adjustment
PW Adjustment
Checking the following parts and replace the defective one:
Checking the PF Encoder FFC (CN8) for disconnection or breakage
Checking the lead wires of the PF Motor (CN13) for disconnection or breakage
Checking the PF scale for adhesion of dirt or damage (p.90)
Checking the PF encoder for adhesion of dirt or damage (p.90)
Checking the Upper Paper Guides for improper installation (p.102)
Checking the PF Motor and replacing it if necessary (p.91)
Main Board (p.78)
Power Supply Board (p.83)
FEH
PF speed over error
FCH
FAH
Measurement value error in PF Duty
limiting control
EFH Position error in PF BS control
F0H DTY_max error in PF BS control
APG motor
70H APG error (normal drive error)
An error occurred in the APG
operating sequence
Checking the installation of the APG Sensor:
position of the sensor and connection of the connector (CN7)
Checking the drive of the APG Unit:
Installation of the composite gear of the ASF Unit - APG Unit
Standalone operation of the APG Unit
Reinstallation of the APG Unit (phase)
Checking the following parts and replace the defective one:
APG Unit (p.95)
ASF Unit (p.93)
APG Sensor (p.36)
PG Left Cam (p.98)
Main Board (p.78)
Power Supply Board (p.83)
71H APG home seek error
72H Error in APG drive by factory command
Motor drive
time error
D1H CR (PID) drive time-out
The motor kept operating for
more than the specified time.
Checking the mechanism and operation:
Check the mechanism and operation of the motor in question.
Checking the connection of the connectors and routing of the lead wires
Checking the motor in question and the following parts and replacing the defective part:
Main Board (p.78)
Power Supply Board (p.83)
D2H CR (load positioning) drive time-out
D3H PF (PID) drive time-out
D4H PF (BS) drive time-out
Table 3-3. Fatal Errors (continued)
Category Error Code Error Cause Remedy