Service manual
Epson Stylus Photo PX650/TX650/TX659/PX660/PX660 Premium/Artisan 635 Revision C
Epson Stylus Photo PX660/PX660 Premium/Artisan 635 Disassembly/assembly 147
Confidential
When installing the Scanner Unit, route the following cables
through the grooves and ribs of the Middle Housing, and secure
the FFC with double-sided tape.
Figure 8-5. Routing the Cables
Cable/FFC Groove Number of Rib
Number of double-
sided tape
Scanner FFC A 5 3
Scanner CR Encoder Cable B 5 ---
Scanner CR Motor Cable C 5 ---
Grounding wire D 7 ---
Groove A
Groove B
Groove C
Groove D
Rear left
Insert slack cables
and FFCs into hole
Groove
Rib
Double-sided tape
After routing the cables, put the ferrite core of the Scanner CR
Motor cable in the groove of the Middle Housing. (See Figure
8-3.)
After routing the cables, secure them with acetate tape and
double-sided tape as shown in Fig. 8-3.
After routing the cables from the Main Board side, insert the
slack cables and FFCs into the hole on the Middle Housing.
(See Figure 8-5.)