Service manual

Epson Stylus Photo PX650/TX650/TX659/PX660/PX660 Premium/Artisan 635 Revision C
Epson Stylus Photo PX660/PX660 Premium/Artisan 635 Disassembly/assembly 145
Confidential
8.2.2.1 Scanner Unit
Parts/Components need to be removed in advance
Upper Housing
Removal procedure
1. Install the Scanner Unit to the printer as instructed in Fig. 8-1.
2. Disconnect the Scanner FFC (CN19), the Scanner CR Motor Cable (CN17) and
the Scanner CR Encoder Cable (CN20) from the connector on the Main Board.
3. Remove the screw that secure the grounding wire.
Figure 8-2. Removing the Scanner Unit (1)
C H E C K
P O I N T
This section describes the disassembly/reassembly procedures of the
Scanner Unit for Epson Stylus Photo PX660/PX660 Premium/
Artisan 635.
C A U T I O N
The Scanner Unit is not secured to the printer when removing
the Upper Housing using a general screwdriver. However, when
removing the Upper Housing using the tools specified in the
check point in
p.66
, the Scanner Unit is secured to the printer;
therefore, make sure to follow the check point in the steps and
remove the screws that secure the Scanner Unit and the hinges.
It is difficult to remove/attach the cables with holding the
Scanner Unit; therefore, the following explains the procedure
while engaging the hinges without securing them by screws as
shown below. Be careful for handing them, since the hinge
sections may break easily when opening/closing the Scanner Unit.
Figure 8-1. Scanner Unit
Be careful not to break hinge sections
if these are not secured with screws.
Right
Groove
Rib
Hinge
Engage groove of Scanner Unit
with rib of the right hinge.
Left
Hole
Hinge
Insert left hinge to hole
of Middle Housing.
Scanner Unit
C.B.P. 3x10 (6±1 Kgfcm)
Scanner FFC
Scanner CR Encoder Cable
Scanner CR Motor Cable
CN 19
CN 17CN 20
Grounding wire
Top of Main Board