Service manual
Epson Stylus Photo PX650/TX650/TX659/PX660/PX660 Premium/Artisan 635 Revision C
MAINTENANCE Overview 134
Confidential
LUBRICATION OF CR UNIT AND CR GUIDE SHAFT
LUBRICATION AT INSTALLATION OF CR UNIT
LUBRICATION OF APG UNIT
Lubrication
Points
CR Guide Shaft and CR
Unit
Type G-71
Amount of
Application
Area A:
210±20 mg (x2)
Area B:
210±20 mg (x2)
Applying
Tool
Injector
Precautions
Make sure that the belt
and any parts other than
those specified are free
from grease.
Lubrication
Points
Right and Left PG
Cams (Cam Contour)
Type G-71
Amount of
Application
ø 1 x One round
Applying
Tool
Injector
Precautions ---
Area A Area A
Area A: Inject 210 ± 20 mg of G-71
into the hole
Area B: Apply 210 ± 20 mg of G-21
to the CR Guide Shaft in its
middle area.
G-71
Left side of
printer frame
Right side of
printer frame
G-71
Lubrication
Points
CR Guide Shaft
(Grooves for pressure
springs)
Type G-71
Amount of
Application
(1) ø 1 x 5 mm (x2)
(2) ø 1 x 10 mm (x1)
(3) ø 1 x 15 mm (x1)
Applying
Tool
Injector
Precautions ---
Lubrication
Points
Upper part of the shaft
holders (5 points)
Type G-71
Amount of
Application
ø 3 x One round (x5)
Applying
Tool
Injector
Precautions
Disassemble the APG
Unit and apply grease
before installing the
APG Unit.
Lubrication
Points
Around the Spur gear
28.8
Type G-71
Amount of
Application
ø 3 x One round
Applying
Tool
Injector
Precautions
Apply grease before
installing the APG
Unit.
G-71
Left side of
printer frame
Right side of
printer frame
G-71
Shaft holder
Lubrication point
G-71
2mm
G-71