7. Fit the round cutouts in SCALE, PF to the protrusions on SPUR GEAR
(76) making sure the scale and the gear are parallel. But note you
dont attach the scale to the gear yet.
8. Attach SCALE, PF to the gear using Scale PF unit Assembling tool
(AS tool code: 1051767).
Figure 4-63. Loop Scale Installation
SPUR GEAR, 76
Protrusions
Tool (#1051767)
SCALE, PF
CHECK
PO INT
!
Check that the protrusions on the gear (76) are sticking
out from the cutouts in the scale.
!
Ensure SCALE, PF is free form any dirt or damage.
Cutout
Protrusion