Disassembly and Assembly Disassembly and Assembly of Other Parts 59
4.6 Disassembly and Assembly of Other Parts
4.6.1 Damper Assembly
1. Panel Unit Removal. (p41)
2. Remove the Main Board Unit. (p.60) (as needed)
3. Remove a screw that secures the damper assembly, and remove it from the middle
housing.
4.6.2 Stacker
1. Panel Unit Removal. (p41)
2. Scanner Unit Removal. (p42)
3. Middle Housing Removal. (p43)
4. Remove the stacker by sliding forward while pushing projected areas located right
stacker.
Figure 4-19. Damper Assembly Removal
Figure 4-20. Stacker Removal
For installing the damper assembly, close the slot cover, and follow
the conditions as shown oi the figure below:
Damper Assembly
C.B.P Tite 3x10,F/ZN
Tightening torque
:0.6 ± 0.1 N
m
Slot Cover
Stacker