Service manual
EPSON Stylus COLOR 480 Revision B
Disassembly and Assembly Disassembly 85
4.2.8 HP/PE/IC Sensor removal
1. Remove the Housing from the printer. (Section 4.2.1 Housing removal)
2. Remove the LD roller from the LD roller shaft holder. (Section 4.2.7 LD Roller
removal)
3. Remove HP/IC detection lever from the LD roller shaft holder and disconnect the cable
from the sensor connector.
Figure 4-30. Removing the HP/IC detection lever
4. Release the two fixing hooks for the sensor from the LD roller shaft holder and remove
the sensor.
Figure 4-31. Releasing two fixing hooks for the sensor
HP/IC detection lever
HP/PE/IC sensor
Two fixing hooks
CHECK
POINT
Tor
n
Make sure that the Torsion spring 0.22 is hung to the following
suitable position.
Figure 4-32. Torsion spring 0.22 for PE sensor lever
Figure 4-33. Torsion spring 0.22 for HP/IC sensor lever
Torsion spring 0.22
PE sensor lever
Torsion spring 0.22
HP/IC sensor lever