Service manual

Chapter 1 Product Descriptions
Rev. A
1-
9
1.2.9 Electrical Specifications
Table 1-7. Electrical Specification
Item 120V Version
220
240V Version
Rated Voltage 120 VAC
220 240 VAC
Input Voltage
Range
103.5 132 V 198 264 V
Rated Frequency
Range
50 60 Hz 50 60 Hz
Input Frequency
Range
49.5 60.5 Hz 49.5 60.5 Hz
Rated Current 0.5 A
(Max. 0.5 A)
0.3 A
(Max. 0.3 A)
Power
Consumption
Approx. 15 W
(ISO/IEC10561 LETTER pattern)
Approx. 15 W
(ISO/IEC10561 LETTER pattern)
Energy Star Compliant
Insulation
Resistance
10 M, Min.
(applying 500 VDC between AC
line and chassis)
10 M, Min.
(applying 500 VDC between AC
line and chassis)
Dielectric
Strength
AC 1000 Vrms for 1 min. or
AC 1200 Vrms for 1 sec.
(between AC line and chassis)
AC 1500 Vrms for 1 min.
(between AC line and chassis)
1.2.10 Environmental Conditions
Table 1-8. Environmental Conditions
Condition Operating Non operating
Temperature
10 35 °C 3 -20 60 °C 1
Humidity
20 80 % 2/3 5 85 % 1/2
Shock
Resistance
1G
(within 1 ms)
2G
(within 2 ms) 1
Vibration
Resistance
0.15G
0.50G 1
Note)
1: Applicable when the unit is in a shipping container.
2: Without condensation.
3: The unit should be operated within the range shown in figure below.
10
27
35
80
55
20
Humidity
(%)
Temperature
(°C)
Figure 1-5. Temperature and Humidity Range