Specifications

S1D15300 Series
Rev.1.4 EPSON 5–23
Command
Code
Function
A0 RD WR D7 D6 D5 D4 D3 D2 D1 D0
(1) Display ON/OFF 0 1 0 1 0 1 0 1 1 1 0 Turns on LCD panel when goes
1 high, and turns off when goes low.
(2) Initial Display Line 0 1 0 0 1 Start display address Specifies RAM display line for
COM0.
(3) Set Page Address 0 1 0 1 0 1 1 Page address Sets the display RAM page in
Page Address register.
(4) Set Column Address 0 1 0 0 0 0 1 Higher column Sets 4 higher bits of column
4 higher bits address address of display RAM in register
(4) Set Column Address 0 1 0 0 0 0 0 Lower column Sets 4 lower bits of column
4 lower bits address address of display RAM in register
(5) Read Status 0 0 1 Status 0 0 0 0 Reads the status information.
(6) Write Display Data 1 1 0 Write data Writes data in display RAM.
(7) Read Display Data 1 0 1 Read data Reads data from display RAM.
(8) ADC Select 0 1 0 1 0 1 0 0 0 0 0 Sets normal relationship between
1 RAM column address and seg-
ment driver when low, but re-
verses the relationship when high.
(9) Normal/Reverse Display 0 1 0 1 0 1 0 0 1 1 0 Normal indication when low, but
1 full indication when high.
(10) Entire Display ON/OFF 0 1 0 1 0 1 0 0 1 0 0 Selects normal display (0) or
1 Entire Display ON (1).
(11) Set LCD Bias 0 1 0 1 0 1 0 0 0 1 0 Sets LCD drive voltage bias ratio.
1
(12) Read-Modify-Write 0 1 0 1 1 1 0 0 0 0 0 Increments Column Address
counter during each write when
high and during each read when
low.
(13) End 0 1 0 1 1 1 0 1 1 1 0 Releases the Read-Modify-Write.
(14) Reset 0 1 0 1 1 1 0 0 0 1 0 Resets internal functions.
(15) Set Output Status 0 1 0 1 1 0 0 0 * * * Selects COM output scan
Register 1 direction. * Invalid data
(16) Set Power Control 0 1 0 0 0 1 0 1 Operation Selects the power circuit
status operation mode.
(17) Set Electronic Control 0 1 0 1 0 0 Electronic control value Sets V5 output voltage to Elec-
Register tronic Control register.
(18) Set Standby 0 1 0 1 0 1 0 1 1 0 0 Selects standby status.
1 0: OFF 1: ON
(19) Power Save Compound command of display
OFF and entire display ON
(20) Test Command 0 1 0 1 1 1 1 * * * * IC Test command. Do not use!
(21) Test Mode Reset 0 1 0 1 1 1 1 0 0 0 0 Command of test mode reset
Note: Do not use any other command, or the system malfunction may result.