User's Manual
Table Of Contents
- Introduction
- Basic Operations
- Loading and Removing the Roll Paper
- Loading and Removing Cut Sheets
- Loading and Removing Poster Board
- Viewing and Changing Media Settings
- Replacing Paper
- Using the Paper Basket (T7270/T5270/T3270)
- Using the Large-Capacity Paper Basket (T7270D/T5270D)
- Using the Auto Take-up Reel Unit (T7270 Only)
- Basic Printing Methods (Windows)
- Basic Printing Methods (OS X)
- Printable area
- Using the Power Off Timer
- Canceling Printing
- Saving to and Reprinting on the Optional Hard Disk Unit
- Copying and Scanning
- Print From Folder
- More Ways to Print
- Enlargements and Horizontal and Vertical Banners
- Printing at Non-Standard Sizes
- Printing CAD Drawings
- Switching Roll Paper Automatically before Printing (T7270D/T5270D Only)
- Borderless Printing
- Correct color and print
- Multi-Page/Poster Printing
- Printing Multiple Documents (the Layout Manager) (Windows Only)
- Color Management Printing
- Tips for Using the Printer Driver (Windows)
- Tips for Using the Printer Driver (OS X)
- Using the Control Panel Menu
- Maintenance
- Problem Solver
- Appendix
- Where To Get Help
- Software License Terms
Epson SureColor T-Series User’s Guide
Problem Solver
196
Feed Adjust (Multifunction Scanner)
If the print results and document length of
copied/scanned files do not match, use the following
procedure to adjust document feeding. Differences in
length may occur due to the paper type used for
printing.
1
At Large copy/Large scan screen, use the d/u
buttons to select Scanner Maintenance and
press the Z button.
2
Use the d/u buttons to select Feed Adjust and
press the Z button.
3
An adjustment setting screen will be displayed.
Press the d/u button to display the target
adjustment value, and then press the Z button.
The following section shows how the
adjustment values are calculated.
Example) Document length: 50 cm, print result:
50.1 cm
50/50.1 x 100-100=-0.1996, rounded at the
second decimal place
Adjustment value: -0.2
4
After the adjustment value has been set, press
the W button to exit.
Note:
Store the calibration sheet so it does not become soiled
or folded.