User's Manual
Table Of Contents
- Introduction
- Basic Operations
- Loading and Removing the Roll Paper
- Loading and Removing Cut Sheets
- Loading and Removing Poster Board
- Viewing and Changing Media Settings
- Replacing Paper
- Using the Paper Basket (T7270/T5270/T3270)
- Using the Large-Capacity Paper Basket (T7270D/T5270D)
- Using the Auto Take-up Reel Unit (T7270 Only)
- Basic Printing Methods (Windows)
- Basic Printing Methods (OS X)
- Printable area
- Using the Power Off Timer
- Canceling Printing
- Saving to and Reprinting on the Optional Hard Disk Unit
- Copying and Scanning
- Print From Folder
- More Ways to Print
- Enlargements and Horizontal and Vertical Banners
- Printing at Non-Standard Sizes
- Printing CAD Drawings
- Switching Roll Paper Automatically before Printing (T7270D/T5270D Only)
- Borderless Printing
- Correct color and print
- Multi-Page/Poster Printing
- Printing Multiple Documents (the Layout Manager) (Windows Only)
- Color Management Printing
- Tips for Using the Printer Driver (Windows)
- Tips for Using the Printer Driver (OS X)
- Using the Control Panel Menu
- Maintenance
- Problem Solver
- Appendix
- Where To Get Help
- Software License Terms
Epson SureColor T-Series User’s Guide
Problem Solver
195
1
Align the loading guide with the calibration
sheet set position.
2
Align the right edge with the loading guide so
that calibration sheet is loaded from the black
side.
3
Insert the calibration sheet horizontally until its
edge touches the inner roller.
The calibration sheet is loaded automatically
until the read start position.
4
After the calibration sheet has been loaded,
remove the loading guide.
5
At Large copy/Large scan screen, use the d/u
buttons to select Scanner Maintenance and
press the Z button.
6
Use the d/u buttons to select Calibration and
press the Z button.
7
If the Z button is pressed, calibration starts.
8
A message is displayed when calibration is
complete. If you follow the message and press
the Z button, the calibration sheet is ejected.
c
Important:
Do not turn off the printer during
calibration. If the printer turned off, the
Multifunction Scanner may malfunction.