Specifications

6 EPSON S1C6P466 TECHNICAL MANUAL
CHAPTER 2: POWER SUPPLY AND INITIAL RESET
CHAPTER 2POWER SUPPLY AND INITIAL RESET
2.1 Power Supply
The S1C6P466 operating power voltage is as follows:
Table 2.1.1 Operating power voltage
Operating mode
MCU normal operation mode
PROM programming mode
Operating power voltage
2.7 V–5.5 V
5.0 V ±10%
The S1C6P466 operates by applying a single power supply within the above range between VDD/VDDF
and VSS. The S1C6P466 generates the voltage necessary for all the internal circuits by the built-in power
supply circuits shown in Table 2.1.2. Supply the same voltage level as V
DD to the VDDF terminal from
outside the IC.
Table 2.1.2 Power supply circuits
Circuit
Oscillation circuit
LCD driver
Power supply circuit
Oscillation system voltage regulator
LCD system voltage circuit
Output voltage
V
D1
V
C1
–V
C5
Notes: Do not drive external loads with the output voltage from the internal power supply circuits.
The internal LCD system voltage circuit (1/4 bias) is always used in the S1C6P466, connect
between VC3 and VC2 terminals.
See Chapter 9, "Electrical Characteristics", for voltage values and drive capability.
External
power
supply
Oscillation
circuit
LCD system
voltage circuit
Oscillation system
voltage regulator
V
DD
V
V
C5
OSC1–4
COM0–16
SEG0–59
D1
V
V
V
V
V
CA
CB
CC
CD
CE
CF
C1
C2
C3
C4
C5
LCD driver
V
SS
+
V –
V
D1
C1
VDDF
Fig. 2.1.1 Configuration of power supply