8 MAINTENANCE AND WARRANTY
S5U1C63000H6 MANUAL
EPSON
19
(S1C63 Family In-Circuit Emulator)
8 Maintenance and Warranty
8.1 Self-Diagnostic Test
The self-diagnostic test is executed by starting the debugger after setting the DIAG switch on the front panel to “ON”
position and then turning the S5U1C63000H6 on.
The debugger displays the messages shown below during the start-up sequence.
Debugger for S1C63 Ver. x.xx
Copyright (C) SEIKO EPSON CORP. 1998-xxxx
Connecting USB ... done
DIAG test, please wait 1 min ... done ← <1>
Parameter file name : Par63xxx.par
Version : xx
Chip name : xxxxx
CPU version : x.x
PRC board version : x.x
LCD board version : x.x
EXT board version : x.x
ICE hardware version : x.x
ICE software version : x.x
DIAG test : OK.
Map ............................. done
Initialize ...................... done
>
When an error is detected in the diagnosis, the error message is displayed at the point <1> instead of “done.”
If an error message is displayed, stop using the S5U1C63000H6, as it may have a hardware failure.
This self-diagnostic test takes about one minute for its precise inspection until it is completed and the
S5U1C63000H6 is ready to accept commands.
8.2 Warranty
Please refer to the warranty card included in the package for the warranty details.