Product specifications
8 EPSON S5U1C60N15E MANUAL
(EVALUATION BOARD FOR S1C60N15)
4 CABLE CONNECTION
4.2 Power Cable Connection
When using the S5U1C60N15E on its own, it must be supplied with power (5 V DC, 3 A or more) from an
external source through the power cable.
When the S5U1C60N15E is connected to the ICE, power is supplied by the ICE; therefore, the power cable
is not necessary. Disconnect the power cable if it is already connected.
Figure 4.2.1 shows the connection of the power cable pins.
-
+
Connect to the
power connector
of the S5U1C60N15E
Connect to the
external power
supply
Black
Red
Fig. 4.2.1 Connection of power cable pins
4.3 Connection to Target System
The I/O #0, I/O #1 and LCD #0 connectors
a
re used to connect the S5U1C60N15E to the target system.
S5U1C60N15E
I/O #0
Front
I/O cable
LCD cable
I/O
LCD
Target
system
connectors
connector
LCD #0
I/O #1
Fig. 4.3.1 Connection of target system
The signals output from the LCD #0 connector are the same as those of the actual IC at the function level.
Therefore, the S5U1C60N15E may be connected to the LCD of the target system without any changes.