Specifications

II-66 EPSON S1C6S2N7 TECHNICAL SOFTWARE
CHAPTER 4: SUMMARY OF PROGRAMMING POINTS
CHAPTER 4
Core CPU
Power Supply
SUMMARY OF PROGRAMMING
POINTS
After the system reset, only the program counter (PC),
new page pointer (NPP) and interrupt flag (I) are initial-
ized by the hardware. The other internal circuits whose
settings are undefined must be initialized with the pro-
gram.
External load driving through the output voltage of
constant voltage circuit or voltage booster is not
permitted.
Data Memory Since some portions of the RAM are also used as stack
area during sub-routine call or register saving, see to it
that the data area and the stack area do not overlap.
The stack area consumes 3 words during a sub-routine
call or interrupt.
Address 00H–0FH in the RAM is the memory register area
addressed by the register pointer RP.
Memory is not mounted in unused area within the mem-
ory map and in memory area not indicated in this man-
ual. For this reason, normal operation cannot be assured
for programs that have been prepared with access to
these areas.
Initial Reset Maintain the initial reset circuit at high level for at least 4
seconds (in case of oscillation frequency fosc = 32 kHz)
because noise rejector is built-in.
When utilizing the simultaneous high input reset func-
tion of the input ports (K00–K03), take care not to make
the ports specified during normal operation to go high
simultaneously.