Specifications
Table Of Contents
- Technical Hardware
- 1 OVERVIEW
- 2 POWER SUPPLY AND INITIAL RESET
- 3 CPU, ROM, RAM
- 4 PERIPHERAL CIRCUITS AND OPERATION
- 4.1 Memory Map
- 4.2 Resetting Watchdog Timer
- 4.3 Oscillation Circuit
- 4.4 Input Ports (K00–K03, K10)
- 4.5 Output Ports (R00–R03)
- 4.6 I/O Ports (P00–P03, P10–P13, P20–P23)
- 4.7 LCD Driver (COM0–COM3, SEG0–SEG31)
- 4.8 Clock Timer
- 4.9 Stopwatch Timer
- 4.10 Programmable Timer
- 4.11 Serial Interface (SIN, SOUT, SCLK, SRDY)
- 4.12 A/D Converter
- 4.13 General-purpose Operation Amplifier (AMP)
- 4.14 SVD (Supply Voltage Detection) Circuit
- 4.15 Interrupt and HALT/SLEEP
- 5 SUMMARY OF NOTES
- 6 DIAGRAM OF BASIC EXTERNAL CONNECTIONS
- 7 CHARACTERISTICS
- 8 PACKAGE
- 9 PAD LAYOUT
- Technical Software
- 1 INTRODUCTION
- 2 BLOCK DIAGRAM
- 3 PROGRAM MEMORY (ROM)
- 4 DATA MEMORY
- 5 INITIAL RESET
- 6 PERIPHERAL CIRCUITS
- 6.1 Watchdog Timer
- 6.2 OSC3
- 6.3 Input Ports (K00–K03 and K10)
- 6.4 Output Ports (R00–R03)
- 6.5 I/O Ports (P00–P03, P10–P13 and P20–P23)
- 6.6 LCD Driver
- 6.7 Clock Timer
- 6.8 Stopwatch Timer
- 6.9 Programmable Timer
- 6.10 Serial Interface Circuit
- 6.11 Amplifier
- 6.12 SVD (Supply Voltage Detection) Circuit
- 6.13 A/D Converter
- 6.14 Sleep
- 6.15 Interrupt
- 7 SUMMARY OF NOTES
- APPENDIX

S1C62740 TECHNICAL SOFTWARE EPSON II-61
CHAPTER 6: PERIPHERAL CIRCUITS (A/D Converter)
Measurement mode selection
The A/D converter can measurement the following mode:
• Terminal voltage vs GND
• Difference voltage between terminal
• Resistance between terminal
How to set the measurement mode and measurement terminals are
shown as following:
Table 6.13.4 Measurement item selection
AIS3 AIS2 AIS1 AIS0 AI4 AI3 AI2 AI1 AI0 Measurement items
000000001AI0 voltage measurement (GND reference)
000000010AI1 voltage measurement (GND reference)
000000100AI2 voltage measurement (GND reference)
000001000AI3 voltage measurement (GND reference)
000010000AI4 voltage measurement (GND reference)
000100011AI1 differential voltage measurement (AI0 reference)
001001100AI3 differential voltage measurement (AI2 reference)
010010100AI2 resistance measurement (AI4 reference)
100011000AI3 resistance measurement (AI4 reference)
Note: It is inhibit to set other condition that is not shown on the above table.
A/D conversion
When the above four stages is set properly, then can start the A/D
conversion by set ADON (F6H•D3) = "1". When set ADON to "1", it
means to reset A/D converter and start converting.
Figure 6.13.1 show the integration amplifier's output.
Fig. 6.13.1
Integration amplifier output
Readout the A/D converter and check valid
There are 13 bits for the A/D converter counter data (AD12–AD0).
And with a sign bit ADP for input polarity.
It should be read the A/D converter counter data from the lowest
word to highest word, then check the valid bit IDR. If IDR = "1",
means the data is invalid.
ADON = "1" ADON = "1"
reset and start
(even though ADON
already set to "1")