Technical information

5. CONNECTION
S1C33 Family In-Circuit Debugger EPSON 21
S5U1C33001H1400 Manual (Rev. 0.20)
30-pin connector
No. Pin
name
I/O Pin function No. Pin
name
I/O Pin function
1 GND - Power supply (GND) 16 DST2 I Bus trace status 2 signal
2 DCLK I Clock for debugging 17 DTS1 I Bus trace status 1 signal
3 GND - Power supply (GND) 18 DTS0 I Bus trace status 0 signal
4 DSIO I/O Serial I/O signal for debugging 19 GND - Power supply (GND)
5 GND - Power supply (GND) 20 DTD7 I Bus trace data 7 signal
6 DST2 I Debug status 2 signal 21 DTD6 I Bus trace data 6 signal
7 GND - Power supply (GND) 22 DTD5 I Bus trace data 5 signal
8 DST1 I Debug status 1 signal 23 DTD4 I Bus trace data 4 signal
9 GND - Power supply (GND) 24 GND - Power supply (GND)
10 DST0 I Debug status 0 signal 25 DTD3 I Bus trace data 3 signal
11 GND - Power supply (GND) 26 DTD2 I Bus trace data 2 signal
12 DPCO I PC signal 27 DTD1 I Bus trace data 1 signal
13 GND - Power supply (GND) 28 DTD0 I Bus trace data 0 signal
14 DTS4 I Bus trace status 4 signal 29 GND - Power supply (GND)
15 DTS3 I Bus trace status 3 signal 30 DBT I
Bus break trigger signal
Notes:
The signals connected to the S5U1C33001H are very high-speed signals, so the target connector must be mounted
within 5 cm from the S1C33xxx. If there is more distance between the connector and the S1C33xxx chip, the
S5U1C33001H may not work properly.
A 33 resistor must be connected in series to the DSIO signal line between the connector and the S1C33xxx chip.
The resistor should be placed as close to the S1C33xxx as possible.
Be sure to use the supplied 10-pin or 4-pin, or 30-pin cable for Connecting the target system to the S5U1C33001H.
Using another cable may cause a malfunction. Furthermore, do not use the 30-pin cable and 10-pin or 4-pin cable
simultaneously.
Disable the trace function of the S5U1C33001H using DIP switch 4 in the following cases:
- when using the 4-pin cable and connector.
- when the signals (DST0, DST1, DPCO) necessary for tracing are not connected even if the 30-pin or 10-pin cable
and connector is used.
- when the trace function is not used due to some reason even if the 30-pin or 10-pin cable and connector is used
and all the signals are connected.
The 4-pin connector does not have a projection for preventing reverse insertion. Check the cable marker of pin 1 to be
sure the insertion of connector is proper when connecting it to the target system.
The product package does not include a 30-pin cable or the corresponding connector. Please contact us if you need
this cable or the corresponding connector.
Fig. 9 Connecting with 4-pin connectors