Service manual
EPSON Stylus Photo R340/350 Revision A
Disassembly and Assembly Disassembly 79
Illustration (2)
Figure 2-69. Removing the Carriage Unit (2)
8. Remove the E ring from the right edge of the CR Guide Shaft, and remove the
Right Scale Holder, Right CR Cam and the Scale Holder Slider.
9. Remove the screw ( ) that secures the Right Parallel Adjust Bushing and
remove it.
10. Release the CR Shaft Right Fixed Spring from the tab ( ) of the Main Frame,
and remove the spring from the CR Guide Shaft.
11. Remove the upper E ring and flat washer that secure the Left Scale Holder.
12. Remove the lower E ring, flat washer and spring washer that secure the Left
Scale Holder and remove the Left Scale Holder.
13. Slide the CR Guide Shaft rightward to pull it out of the Left CR Cam and
Main Frame, and remove the Carriage Unit together with the CR Guide Shaft.
14. Pull out the CR Guide Shaft from the Carriage Unit.
E Ring
Right CR
Cam
Right Scale
Holder
Right Parallel
Adjust Bushing
C.B.S(P4) 3x6
(6-8kgf.cm)
Right Side of
the Printer
Hooked
Tab
CR Shaft Right Fixed Spring
CR Guide Shaft
Right Side of the Printer
E Ring
Flat Washer
E Ring
Flat Washer
Spring Washer
Left Scale Holder
Left Side of
the Printer
Left CR Cam
C A U T I O N
When performing the next step, be careful not to lose the Scale
Holder Sliders.
Figure 2-70. Scale Holder Sliders
Left Side of the Printer Right Side of the Printer